A customer wants to deploy a FlexPod solution that involves directly connecting the NetApp AFF storage using the FCoE protocol to the Cisco UCS Fabric Interconnects.
In this scenario, which Cisco UCS Fibre Channel mode would be used to accomplish this task?
A. trunk mode
B. end host mode
C. switching mode
D. access mode
The storage administrator must change the vHBA settings bound to a template associated with a production server.
What happens when the settings are reconfigured in this scenario?
A. The vHBA configuration change does not affect LUN access.
B. The server that is associated with the service profile reboots.
C. The service profile template that is associated with the server is initialized.
D. The vHBA template is deleted from UCS Manager.
Click the Exhibit button.

A customer wants to ensure that FlexPod Datacenter connections to the storage layer are highly available. Which two configurations shown in the exhibit satisfy the customer's requirements? (Choose two.)
A. I.
B. II.
C. III.
D. IV
A customer has a FlexPod Express configuration with a FAS2720 system. The company has opened a new remote location and will purchase a FlexPod Express configuration with a FAS2750 system. The business requires that the data be replicated to the new location.
Which two software applications accomplish this task? (Choose two.)
A. SnapVault
B. SnapRestore
C. SnapMirror
D. FlexCache
A customer has several existing standalone Cisco UCS C-Series servers that they would like to repurpose and add to their FlexPod Datacenter solution.
Which action should the customer perform on these servers before using UCS Manager?
A. Zero-out the FlexFlash cards on each server.
B. Reboot the CIMC on each server.
C. Remove the hard disks on each server.
D. Reset the CIMC to the factory settings on each server.
You are designing a FlexPod solution with a 2-node storage system, multiple compute chassis, and ACI.
In this scenario, which two network switches are required? (Choose two.)
A. leaf switch
B. core switch
C. cluster interconnect switch D. spine switch
A customer with a FlexPod Datacenter design that uses a 4-node FAS8200 for storage wants to add a new workload that requires high performance. The customer needs to nondisruptively move some workloads from the existing FAS system to the new storage.
Which storage system would satisfy the requirements?
A. FAS2700
B. AFF A300
C. EF570
D. E2700
You want to deploy a FlexPod Datacenter solution based on the minimum hardware requirements.
Which three components must be deployed in highly available pairs to accomplish this task? (Choose three.)
A. Cisco USC Nexus Switches
B. Cisco UCS 5108 Chassis
C. NetApp FAS Storage Controllers
D. Cisco APICs
E. Cisco UCS Fabric Interconnects
A customer is planning to deploy a FlexPod solution for a large scale SAN requirement that uses the FC protocol. The customer plans to use Smart Zoning in the configurations to reduce the number of TCAM entries in the zoning process.
In this scenario, which design would enable the customer to use Smart Zoning?
A. storage connected to Cisco Nexus 9000 Series switches
B. storage connected to Cisco Nexus 5000 Series switches
C. storage connected to Cisco MDS switches
D. storage directly connected to Cisco UCS Fabric Interconnects
A customer is configuring the UCS to handle a multitenant environment. The customer has created an organization within UCS for each tenant and would like to allow access to these organizations for only users that belong to that tenant.
In this scenario, which feature in UCS Manager should the customer use to accomplish this task?
A. Locales
B. Trusted Platform Module
C. Service Profile
D. User Roles