A physical RecoverPoint cluster is connected to a single VMAX array. When running SAN diagnostics form the boxmgmt menu, what is the minimum number of WWPN can be seen in the storage ports section of the diagnostic test?
A. 1
B. 2
C. 3
D. 4
What is the recommended wait period before running the Balance Load tool?
A. 4 Days
B. 5 Days
C. 6 Days
D. 7 Days
An administrator ran the balance_load command on a RecoverPoint cluster during a high-load issue. However, the administrator forgot to capture the output. Where can the RecoverPoint Cluster Load report be located?
A. In the output from running the "Collection System Information" wizard
B. https://Cluster_Management_IP/info/long_term_statistics
C. https://Cluster_Management_IP/info/load_balancing
D. In the output from the events_log
Where are incoming writes sent to during the Write phase of the RecoverPoint workflow?
A. Production Journal
B. Consistency Groups' assigned RPA
C. Remote clusters' primary RPA
D. Copy Journal
Which tools are listed under "System Analysis and Tools" selection of Unisphere for RecoverPoint?
A. Users and Security, Configure System Reports and Alerts, Collect System Information
B. Detect Bottlenecks, Balance Load, Configure System Reports and Alerts
C. Users and Security, Configure System Reports and Alerts, Change Security Level
D. Detect Bottlenecks, Balance Load, Collect System Information
A RecoverPoint administrator wants to use the compression setting to save bandwidth in their environment. What will be the impact of changing the link compression setting on a Consistency Group?
A. Short initialization
B. Temporary high-load
C. Journal history will be lost
D. Long resynchronization
When attempting to protect new XtremIO LUNs, the administrator is unable to add an XtremIO source LUN to the Consistency Group.
What is a possible reason for this issue?
A. XtremIO array was not licensed in RecoverPoint
B. RecoverPoint/EX only allows the protection of VNX arrays
C. XtremIO LUN was created with a 512-byte block size
D. XtremIO arrays are only protected with RecoverPoint for VMs.
Which type of I/O modules can be inserted into Slot1 of a Gen-6 RPA?
A. 1 GbE optical or 1 GbE copper
B. 10 GbE optical or 1 Gb RJ45 copper
C. 10 GbE optical or 10 GbE copper
D. 10 GbE copper or dual-stacked DB-9 ports
A storage administrator is unable to perform Direct Access to a copy in their RecoverPoint environment. Which array type has this limitation with regards to RecoverPoint copies?
A. XtremIO
B. VMAX
C. VNX
D. VPLEX
A storage administrator has seen high-load events in their RecoverPoint environment. The administrator wants to review the performance data for the past week with RecoverPoint. In addition, the administrator wants the raw data saved to a spreadsheet to review and create graphs of system performance over a period of time.
Which CLI command should be used?
A. get-rpa_statistics
B. export_statistics
C. balance_load