Pass4itsure > EMC > DCS-IE > DES-4421 > DES-4421 Online Practice Questions and Answers

DES-4421 Online Practice Questions and Answers

Questions 4

DRAG DROP

Match each feature with its associated PowerEdge server management tool.

Select and Place:

Buy Now
Questions 5

DRAG DROP

Match the M840c components to the callouts shown in the exhibit.

Select and Place:

Buy Now
Questions 6

An MX7000 administrator has been tasked to create a Scalable Fabric Architecture on a 3 chassis setup using Fabric B. Which IOM configuration is recommended?

A. Chassis 1 - Slot B1: MX9116n; Slot B2: MX9116n Chassis 2 - Slot B1: MX5108n; Slot B2: MX5108n Chassis 3 - Slot B1: MX5108n; Slot B2: MX5108n

B. Chassis 1 - Slot B1: MX7116n; Slot B2: MX7116n Chassis 2 - Slot B1: MX7116n; Slot B2: MX7116n Chassis 3 - Slot B1: MX9116n; Slot B2: MX9116n

C. Chassis 1 - Slot B1: MX9116n; Slot B2: MX7116n Chassis 2 - Slot B1: MX7116n; Slot B2: MX9116n Chassis 3 - Slot B1: MX7116n; Slot B2: MX7116n

D. Chassis 1 - Slot B1: MX9116n; Slot B2: MX5108n Chassis 2 - Slot B1: MX5108n; Slot B2: MX9116n Chassis 3 - Slot B1: MX5108n; Slot B2: MX5108n

Buy Now
Questions 7

In the assigned mapping of the MX5016s storage sled what is an assignment option used for independent storage to be mapped to a compute sled?

A. Drive-assigned enables the MX5016s to be split among multiple compute sleds. Each compute node only "sees" the disks that are assigned to it and not the others.

B. Drive-assigned enables the MXG610s to the first eight drives in the MX5016s.

C. Enclosure-assigned enables the MX5016 to be split among multiple compute sleds. Each compute node only "sees" the disks that are assigned to it and not the others.

D. Enclosure-assigned enables the MXG610s to the first eight drives in the MX5016s.

Buy Now
Questions 8

Which MX7000 feature allows an administrator to virtualize network WWN and MAC addresses?

A. FlexAddress

B. MX Scalable Architecture

C. Identity Pool

D. Virtual Top of Rack

Buy Now
Questions 9

When running an Open Networking operating system, which IOM functions are provided through OME-M?

A. Global and privileged configuration modes

B. Power control and global configuration mode

C. Hardware health and power control

D. Hardware health and global configuration mode

Buy Now
Questions 10

A company receives their first MX7000 chassis. They connect all the provided power supply cables into two different PDUs on different power grids for redundancy. Each of the six power supplies is cabled and has green LEDs. One Management Module is present along with all system fans. Grid redundancy is configured as the power redundancy mode. The chassis is fully populated with six compute sleds and one IOM but only two of the six sleds will power on.

What is the possible reason for this issue?

A. An additional IOM is required to power on and manage the remaining sleds.

B. Two Management Modules are required to power on the populated chassis.

C. Power supply unit redundancy policy was not used.

D. Mixed high line and low line AC inputs in the same chassis is not supported.

Buy Now
Questions 11

While servicing an MX7000 chassis a system administrator logs into OME-M and receives a Chassis Mismatch error. What should be the next step taken by the administrator?

A. Clear the configuration

B. Reset Peer or the Local IOM

C. Perform firmware update

D. Force Active/Clear configuration

Buy Now
Questions 12

Which feature requires an iDRAC Enterprise license for an MX sled?

A. iDRAC Service Module

B. Last Crash Screen

C. Group Manager

D. Storage Management

Buy Now
Questions 13

What is the maximum possible weight of a fully populated MX7000 chassis?

A. 250 Ibs (114 kg)

B. 300 Ibs (136 kg)

C. 400 Ibs (182 kg)

D. 500 Ibs (227 kg)

Buy Now
Exam Code: DES-4421
Exam Name: Specialist - Implementation Engineer, PowerEdge MX Modular Exam
Last Update: Apr 19, 2024
Questions: 54
10%OFF Coupon Code: SAVE10

PDF (Q&A)

$45.99

VCE

$49.99

PDF + VCE

$59.99