DRAG DROP

What is the correct sequence of steps to enable MPIO on a Microsoft Windows 2012 Server?

Select and Place:

Buy Now
Questions 5

A customer notices a volume is using an above average amount of Tier 1 RAID 10 space. What can be done to force this data into a lower RAID set/Tier?

A. Stop I/O to the volume

B. Change the storage profile of the volume

C. Take a manual snapshot

D. Move data to a different volume

Buy Now
Questions 6

Which SC Series licenses are applied at the factory?

A. SC4020 and SC7020

B. SC7020 and SCv2000

C. SC8000 and SC9000

D. SCv2000 and SC8000

Buy Now
Questions 7

Which SC Series array feature simplifies iSCSI connectivity and allows access to all ports through redirection?

A. Legacy Port Mode

B. ISNS

C. ALUA

D. Virtual Port Mode

Buy Now
Questions 8

During the initial installation of a new SC9000 Storage Center, which Dell Storage Manager (DSM) Client option should be selected?

A. Configure this host to access a Storage Center

B. Configure VMware vSphere to access a Storage Center

C. Discover and Configure Uninitialized SCv2000 or SC7000 Series Storage Centers

D. Login to a Storage Center or Data Collector

Buy Now
Questions 9

A customer wants to have the SED feature enabled through Dell Storage Manager (DSM) 2016 R2. How is encryption enabled on the SED?

A. SED feature must be licensed.

B. External KMS is required and must be activated during installation of the array.

C. SED feature uses a dedicated ASIC in each controller and can be enabled at any time.

D. SED encrypts data by default.

Buy Now
Questions 10

You are installing an SC8000 array and the customer notices that each of the controllers only have 16 GB of memory. The customer wants to maximize this memory. What is the maximum RAM supported on a single SC8000 controller?

A. 32 GB

B. 64 GB

C. 128 GB

D. 256 GB

Buy Now
Questions 11

During the addition of an SCv360 enclosure to a SCv3020 the PCle SAS card is used for connectivity. The enclosure is NOT recognized by the system, why?

A. SCv3020 does not allow enclosure expansion

B. SCv2360 is unsupported for enclosure expansion

C. SCv3020 does not support 12Gb SAS

D. PCle SAS is unsupported for enclosure expansion

Buy Now
Questions 12

Refer to the exhibit.

The servers are zoned to best practices. The output of the switch is shown below:

Which is the Physical Zone of Fault Domain B?

A. Zone_A

B. Zone_C

C. Zone_D

D. Zone_B

Buy Now
Questions 13

When a SC is in a failover state what will occur in the surviving controller?

A. Data and metadata will be available

B. The read cache that is associated with the failed controller will be created

C. The deduplication dictionary from the failed controller will load

D. Deduplication will run