What describes Dell EMC PowerStore X front-end cabling?
A. Uses internal VMware virtual switching and does not require a management network
B. Storage and management use the same LACP bonded cable connection
C. Uses VLTi data switch interconnectivity to support vMotion networks
D. Management and discovery use the same cables and connections as storage
Through which network do external hosts connect to the cluster for data access?
A. Management
B. ICM
C. ICD
D. Storage
What describes the power requirements for Dell EMC PowerStore?
A. Lower model numbered systems require less AC line current than higher model numbered systems
B. T models require less total power than X models
C. X models require less total power than T models
D. Lower model numbered systems require less input voltage (VAC) than higher model numbered systems

Refer to the exhibit.
What is indicated when the circled LED on the node embedded module is illuminated solid amber?
A. System is booting
B. Module is faulted
C. Node is faulted
D. Cluster is uninitialized

Refer to the exhibit.
What type of cable is used for the ToR switch configuration shown for the S5248F-ON switches?
A. 10 GigE Cat 6 Ethernet RJ-45
B. 25 GigE Twinax
C. 100 GigE QSFP28
D. 10 GigE SFP optical cable
What is the alert severity if the license expiration date is within a week?
A. Warning
B. Minor
C. Major
D. Information
What does the output of the command "svc_diag list --basic" show?
A. Failover status
B. Master_appliance_ID
C. License status
D. Boot mode
A Storage Administrator notices two fans in a Dell EMC PowerStore are faulted. What describes the system behavior in this circumstance?
A. A five-minute timer starts upon the second fan fault and the system shuts down automatically after the timer expires
B. CPU clock speed is reduced by 50% to lower internal temperatures and the system continues normal operations
C. An increased fan speed signal is sent to the surviving fans and the system continues normal operations
D. Upon the second fan fault, all host I/O is terminated immediately and the PowerStore goes through the halt and vault process and shuts down
A Storage Administrator needs to add drives to a base enclosure of a Dell EMC PowerStore 3000X system. The system currently contains 10 750-GB NVMe SCM drives. Which drive configuration maximizes the base enclosure capacity?
A. 11 750-GB NVMe SCM drives in skits 10-20
B. 13 15360-GB NVMe SSD drives in slots 10-22
C. 13 750-GB NVMe SCM drives in slots 10-22
D. 11 15360-GB NVMe SSD drives in slots 10-20
What describes the SAS cabling when adding an expansion enclosure to a Dell EMC PowerStore, for each node and expansion enclosure side?
A. SAS cabling goes from existing A ports to new В ports. At the last enclosure, SAS cabling returns from the A ports to the originating node's B ports
B. SAS cabling goes from existing A ports to new В ports. At the last enclosure, SAS cabling returns from the A ports to the alternate node's В ports
C. SAS cabling goes from existing В ports to new A ports. At the last enclosure, SAS cabling returns from the В ports to the alternate node's A ports
D. SAS cabling goes from existing В ports to new A ports. At the last enclosure, SAS cabling returns from the В ports to the originating node's A ports