Pass4itsure > Dell > Dell Certifications > DCPPE-200 > DCPPE-200 Online Practice Questions and Answers

DCPPE-200 Online Practice Questions and Answers

Questions 4

An engineer needs to re-purpose the storage of the chassis. Data must NOT be lost when a drive fails. The configuration needs to allow for redundancy with the maximum amount of usable space.

What should the engineer create to perform this task?

A. RAID 60

B. RAID 50

C. RAID 5

D. RAID 6

Buy Now
Questions 5

An engineer is adding an additional server to a chassis with 15 existing servers. The new server will NOT power on in any slot, even known good.

Existing server configuration

-Dual processor

-256GB Memory

-PERC RAID Controller

-2x 1TB 7200RPM SATA HDD

-

QLogic Dual Port 10GbE Network Daughter Card (Fabric A)

-

QLogic 16Gb Fibre Channel Mezz Card (Fabric B)

New server configuration

-Dual processor

-192GB Memory

-No RAID

-Internal SD Card

-Intel Quad Port 1GbE Network Daughter Card (Fabric A)

-QLogic Dual Port 10GbE CNA Mezz Card (Fabric B)

The details of the chassis are as follows:

-Four 2700W Power Supplies

-Redundancy Policy is configured for Power Supply Redundancy

-

Plugged into 220V AC

Power Monitoring logs show the original server's max draw as 418W each.

Which problem needs to be addressed to fix this issue?

A.

Change the Redundancy Policy to No Redundancy

B.

Add additional power supplies to increase available power

C.

Replace Fabric B card in the new server with a matching fabric type

D.

Swap Fabric A and Fabric B cards in the new server to prevent a mismatch

Buy Now
Questions 6

An engineer is deploying a chassis with four IOAs and connecting it to the top of rack (ToR) switch. The deployment mandate requires that the switches be presented as one logical unit. Future servers can be added to network with the minimal amount of configuration.

The following steps have been completed:

-IOAs are daisy-chained using ports 9 and 10

-Cabled ports 11 and 12 on IOA 1 to the ToR

-

Configured a team on NIC ports 1 and 2 on the server How should the IOMs be configured?

A.

Virtual Link Trunking

B.

Stack

C.

FullSwitch

D.

Programmable MUX

Buy Now
Questions 7

An engineer deploys an FX2 and plugs cables from GB1 and STK/GB2 into the management network switch for path and NIC redundancy. When the chassis is powered up, the management network is adversely affected.

What should the engineer do to fix this issue?

A. Plug the CMC Redundancy Dongle into GB1 and STK/GB2

B. Configure a separate IP address for GB2

C. Turn off STP on the management network switch

D. Change the Management Port 2 setting toRedundant

Buy Now
Questions 8

An engineer needs to replicate BIOS and NIC settings for server nodes installed in the chassis. Which CMC feature should an engineer use to perform this task?

A. AutoConfiguration

B. Chassis Profiles

C. QuickDeploy

D. Server Profiles

Buy Now
Questions 9

An engineer is running an inventory report on a VRTX chassis group for a customer. When the engineer views the report, the engineer notices the inventory of one of the VRTX is missing one of its nodes.

What is the cause?

A. The VRTX group member is in Chassis Power State Off since the node was inserted.

B. The VRTX group member is disconnected from the network at the time of the report.

C. The node's iDRAC is unreachable from the VRTX groupleader's CMC.

D. The node's iDRAC needs to have an Enterprise license installed.

Buy Now
Questions 10

An engineer is installing an M1000e chassis and connecting it to the network in the top of rack (ToR) switch. The entire company's infrastructure is on a single subnet configured as follows.

-IPs10.0.1.0/24

-Gateway10.0.1.1

-DNS10.0.1.3

-DHCP10.0.1.4

-OS IPs10.0.1.10-99

The engineer configures the CMC to use IP 10.0.1.100 and the iDRACs to use the next 16 IPs.

The customer notices the CMC and the iDRAC are having intermittent connectivity issues. The following

troubleshooting steps have been completed:

-Replaced cables from CMCs to ToR

-Failed over CMC

-Configured and tried different ports in ToR

-

Connected the laptop directly to the CMC

Direct connection to the CMC does NOT show any connectivity issues.

What should be done to fix the connectivity issues?

A.

Create DHCP reservations for IP range 100-116

B.

Separate the management network from the production network

C.

Register CMC and iDRAC host named in DNS

D.

Configure a LAG for the CMCs ports to increase bandwidth

Buy Now
Questions 11

An engineer is configuring a new FD332 storage sled into an existing chassis in SLOT 3. The FD332 is NOT being detected by the assigned node.

Which two tasks must an engineer complete so that the FD332 is detected by the node? (Choose two.)

A. Verify firmware is up to date

B. Reseat the FD332

C. Import the PERC license

D. Enable the PERC instorage sled

E. Power cycle the node

Buy Now
Questions 12

An engineer is performing system updates on a large number of systems using OpenManage Essentials. The engineer has been instructed NOT to update network adapter firmware at this time.

How can the engineer exclude a firmware update while still using the Dell Online Catalog source?

A. Delete the firmware update from the local catalog.

B. Disable the firmware update in the catalog view.

C. Filter updates by component to exclude the firmware update.

D. Create a catalog policy to exclude the firmware update.

Buy Now
Questions 13

An engineer has been given a new chassis and needs to configure the iDRACs on all servers prior to deploying an OS on them. The iDRACs need to be configured with IP addresses and a new root password.

What is the most efficient method to perform this task?

A. Use CMC QuickDeploy

B. Use iDRAC QuickLaunch

C. Use CMC Server Profiles

D. Use racadm quickdeploy

Buy Now
Exam Code: DCPPE-200
Exam Name: Dell PowerEdge Professional Exam
Last Update: Jul 02, 2025
Questions: 65
10%OFF Coupon Code: SAVE10

PDF (Q&A)

$49.99

VCE

$55.99

PDF + VCE

$65.99