In Cisco UCS, there are several interfaces involved on the packet path from the vNIC through the adapter, IOM to finally reach Pi
Which is the order of those interfaces, starting from the vNIC?
A. VIF, UIF, HIF, SIR NIF
B. VIF, UIF, HIF, NIF SIF
C. HIF. NIF, UIF, VIF SIF
D. HIF. SIF, VIF, UIF NIF
When server is booting from SAN, which command verifies the PLOGI sessions with the target?
A. Lunmap
B. Lunlist
C. FCMap
D. FCIist
What is the result of enabling the Core File Exporter in UCS Manager?
A. A core dump file will be immediately created and transmitted using HTTP protocol
B. A core dump must be remotely activated by Cisco TAC.
C. A core dump will immediately be generated and will be exported
D. If a subsequent triggering event occurs, a core dump will be generated and sent by TFTP
Which two ports on a pair of Cisco Fabric Interconnects must be properly cabled for the pair to form a cluster? (Choose two )
A. L1 > L1
B. L1 > L2
C. L2 > L2
D. L2 > L1
When booting up a Cisco UCS Server you want to see boot time diagnostic messages of the POST, what action is required for you to do so?
A. Enable Quiet Boot on the Server's BIOS
B. Restart the Server
C. Disable Fast Boot on the Server's BIOS
D. Enable Quiet Boot on the Server's Service Profile
E. Disable Fast Boot on the Server's Service Profile
You are in the process of upgrading your UCS M3 Server to a newer UCS M4 Server. You associate the Service Profile to the new UCS Server, but it fails to boot You suspect of a failed boot hard drive. You check your RAID1 Boot LUN in UCS Manager, but see no error messages
What could be causing the issue?
A. The newer Cisco UCS M4 Server is using flash drives, not hard drives
B. The newer Cisco UCS M4 Server is using disks of larger capacity than the previous UCS M3 Server
C. A misconfiguration on the Service Profile Local Boot Policy
D. A misconfiguration on the Service Profile Local Disk Policy
When configuring UCS SAN Connectivity to a 3rd Party FibreChannel Storage Array that is connecting directly to the UCS Fabric Interconnects, which option is Cisco recommended'?
A. Connect the Storage Array to a RC Storage Port and Enable NPV Mode on the UCS Fabric Interconnects
B. Connect the Storage Array to an Appliance Port and Enable NPV Mode on the UCS Fabric Interconnects
C. Direct connectivity between UCS Fabric Interconnects and FibreChannel Storage Arrays is not supported
D. Connect the Storage Array to a FC Storage Port and Enable Switching Mode on the UCS Fabric Interconnects
E. Connect the Storage Array to an Appliance Port and Enable Switching Mode on the UCS Fabric Interconnects
Which statement is true regarding the UCS Manager GUI is showing "Overall Status Unassociated" in the General tab for a C-series server?
A. The server has a service profile assigned, but has connectivity issues with UCS Manager
B. The server is not properly connected
C. The server does not have a service profile assigned, but has been discovered by UCS Manager
D. The server has been properly connected, but has not been discovered by UCS Manager
When it comes to pinning vNIC traffic from a UCS Server to the Fabric Interconnect uplink what configuration can you perform?
A. You can configure Automatic Uplink Pinning. If an uplink interface fails on one Fabric Interconnect, the server will fail to the first available uplink on the other Fabric Interconnect
B. You can configure Static Uplink Pinning. If an uplink interface fails on one Fabric Interconnect, the server will fail to the first available uplink on the other Fabric Interconnect
C. You can configure Automatic Uplink Pinning. If an uplink interface fails on one Fabric Interconnect the server will fail to the matching uplink on the other Fabric Interconnect
D. You can configure Static Uplink Pinning. If an uplink interface fails on one Fabric Interconnect, the server will fail to the first available uplink on the same Fabric Interconnect
E. You can configure Static Uplink Pinning. If an uplink interface fails on one Fabric Interconnect the server will fail to the matching uplink on the other Fabric Interconnect
In a Cisco UCS Manager, if all KVM sessions to each server fail to start, what is likely causing the problem?
A. Cisco UCS Manager has a problem
B. The Fabric Interconnect to which you are connected has a problem
C. The I/O Modules in the chassis are the problem
D. The workstation you are using to connect to the KVM session is the problem